Connecting to Power

The procedure below describes how to connect the device to the power supply.

Power Specifications

Item

Description

Power Supply

Up to two hot swappable, power supply modules for power load sharing and AC power redundancy in case of failure of one of the modules.

Input Ratings

Single universal power supply 100-240 VAC, 50-60 Hz, 2.5A max.

Output Ratings

12 VDC / 10 A max.

Connection to Electrical Outlet

AC power supply inlet.

The device must be connected (by service personnel) to a socket-outlet with a protective earthing connection.
Use only the AC power cord supplied with the device.

Avertissements:

L’appareil doit être branché à une prise murale à condition qu’elle soit mise à la masse.
Utilisez uniquement le cordon AC fourni avec l’appareil.

ご注意

本製品に添付の電源ケーブルは、Mediant 2600 E-SBC に専用設計されているため、汎用性がありません. 本電源ケーブルを他の機器に使用されないよう、ご注意ください.

You can connect both Power Supply modules (1 and 2), for 1+1 power load-sharing and redundancy. Each module provides an AC power socket on the device's rear panel. If both power modules are used, ensure that you connect each one to a different AC supply socket.
The two AC power sources must have the same ground potential.
To connect the device to the power supply:
1. Connect the AC power cord (supplied) to one of the power sockets located on the rear panel.

Connecting to Power

m4k_cabling_power.png

2. Connect the other end of the power cord to a standard AC electrical outlet (100-240V~50-60 Hz).
3. For load sharing and power redundancy, repeat steps 1 through 2, but using the power socket of the second Power Supply module and connecting this to a different supply circuit.
4. Turn on the power at the power source (if required).
5. Check that the POWER LED on each Power Supply module (front panel) is lit green. This indicates that the device is receiving power.